After server reboot multipath shows no paths.
This document (7016832) is provided subject to the disclaimer at the end of this document.
Environment
SUSE Linux Enterprise Server 11 Service Pack 4 (SLES 11 SP4)
Fiber Channel over Ethernet (FCoE)
Network Bonding
Situation
Jan 1 13:00:00 myserver_name multipathd: my_path: path state = blocked
Manually restarting multipath using "rcmultipathd restart" or forcing a devmap reload using "multipath -r" once the server is up and running after a reboot may resolve the issue until the next reboot.
Resolution
BONDING_MODULE_OPTS='mode=balance-tlb miimon=100'
It likely will also be required to make changes to the network switch configurations, for example disabling switch assisted load balancing.
Cause
Additional Information
Disclaimer
This Support Knowledgebase provides a valuable tool for SUSE customers and parties interested in our products and solutions to acquire information, ideas and learn from one another. Materials are provided for informational, personal or non-commercial use within your organization and are presented "AS IS" WITHOUT WARRANTY OF ANY KIND.
- Document ID:7016832
- Creation Date: 14-Sep-2015
- Modified Date:03-Mar-2020
-
- SUSE Linux Enterprise Server
For questions or concerns with the SUSE Knowledgebase please contact: tidfeedback[at]suse.com