 | ProLiant ML110 Gen11 (Xeon 5512U, 2.1GHz, 28c)
Network Server
SGI | 04 Nov 2025
154440 |
SUSE YES Certified for the following products:
Operating Systems:
|
SUSE® LINUX Enterprise Desktop 10 for AMD64 & Intel64
Service Pack 3 for SUSE® SLED 10 |
Product Description
For more information please visit, https://www.hpe.com/us/en/servers.html
Tested Configuration:
| Computer Type: | Tower |
| Mother Board Revision: | Gen11 |
| BIOS/uEFI: | UEFI: 2.60 (08/07/2025) |
| CPU: | Intel
Xeon® Gold 5512U Processor 2.10 GHz |
| RAM: | 192 GB |
| Ports and Bus Types: | 5 USB Ports 2 PCI Express X16 |
| Video Adapter: | Matrox Graphics Inc.
G200eH3 |
| Host Bus Adapter: | HPE
MR416i-p Gen11
, NVMe |
| Hard Disk Drive: | HPE
1.6TB NVMe Gen4 Mainstream Performance Mixed Use SFF BC U.3 Static Multi Vendor SSD
, NVMe |
| Test Kit: | System Certification Kit 10.0.0-150700.125.6 |
Config Notes
- Install: OS Installed via USB CD/DVD Drive.
- Graphics: For best graphics performance, please download the listed driver at http://www.nvidia.com
- Power management: Sleep / Suspend to RAM / ACPI S3 is not supported on this system.
- Power management: Hibernation / Suspend to Disk / ACPI S4 is not supported on this system.
|
Referenced Bulletins
131313
Adapters and Drivers
| | | | | |
| Matrox Graphics Inc.
G200eH3 |
| | Driver Type: Video Driver | Driver Name: mgag200.ko.zst |
| | Driver Date: 08-Sep-2025 | Driver Size: 37329 |
| | Checksum: 27fdfd9cf5176f0fa2196b9630060c24 |
| | Driver Version: 19F3FD4C78E2311F4BA5526 |
|
| Intel
Ethernet Server Adapter I350-T4 (Quad Port) |
| | Driver Type: LAN Driver | Driver Name: igb.ko.zst |
| | Driver Date: 08-Sep-2025 | Driver Size: 185434 |
| | Checksum: 38f0faf06015da9f79962806fd8aec92 |
| | Driver Version: 4694DAF7C43B810B11AF58C |
|
| HPE
MR416i-p Gen11 |
| | Driver Type: HBA Driver | Driver Name: megaraid_sas.ko.zst |
| | Driver Date: 08-Sep-2025 | Driver Size: 146554 |
| | Checksum: b8bd57699e9bf84a72b16aecf69eed06 |
| | Driver Version: 07.734.00.00-rc1 |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
SGI
46600 Landing Parkway
Fremont
, CA
94538
Voice: 650-960-1980