 | UCSC-C240-M7SN
Network Server
Hewlett Packard Enterprise | 17 Jun 2025
154050 |
SUSE YES Certified for the following products:
Operating Systems:
| SUSE® Linux Enterprise Server 15 for AMD64 & Intel64 with KVM Service Pack 4 for SUSE® SLES 15 |
Product Description
Cisco Rack mount server
Tested Configuration:
| Computer Type: | Rack Mount |
| Mother Board Revision: | 74-127172-01 |
| BIOS/uEFI: | UEFI: C240M7.4.3.4a.0.0513242027 (05/13/2024) |
| CPU: | 2 Intel
Xeon® Platinum 8480+ Processor 2.00 GHz |
| RAM: | 256 GB |
| Video Adapter: | ASPEED
AST1300 |
| Host Bus Adapter: | Micron Technology, Inc.
9100 SSD Non-Volatile Memory Controller |
| Hard Disk Drive: | HPE
1.6TB NVMe Gen4 Mainstream Performance Mixed Use SFF BC U.3 Static Multi Vendor SSD |
| Test Kit: | System Certification Kit 9.2.0-150600.115.3 |
Config Notes
- Install: System installed via network PXE UEFI boot; the OS was installed using the UEFI boot loader and system configuration.
- SR-IOV: System was tested using SR-IOV where a virtual network adapter was given to a SLES 15 SP5 guest. One of the Intel Ethernet Network Adapter X710-T4L adapters was used in this testing.
- Kdump: the KDUMP_CPUS value in the /etc/sysconfig/kdump configuration file must be set to 2 for correct kdump functionality.
|
Adapters and Drivers
| | | | | |
| ASPEED
AST1300 |
| | Driver Type: Video Driver | Driver Name: ast.ko.zst |
| | Driver Date: 12-Mar-2025 | Driver Size: 46641 |
| | Checksum: bdadfafa7e0a5d6131da7557e1f45776 |
| | Driver Version: BEC16C633347CAB89B0B6E5 |
|
| Cisco
UCS VIC 1340 (NIC) |
| | Driver Type: LAN Driver | Driver Name: enic.ko.zst |
| | Driver Date: 12-Mar-2025 | Driver Size: 73735 |
| | Checksum: 4c4800aadb739ff18c09d758236d0f23 |
| | Driver Version: CD2904A4E4E5B48DBEA67E4 |
|
| Micron Technology, Inc.
9100 SSD Non-Volatile Memory Controller |
| | Driver Type: HBA Driver | Driver Name: nvme.ko.zst |
| | Driver Date: 12-Mar-2025 | Driver Size: 44387 |
| | Checksum: 907f55511a9d8d76b3b7dcf9bbf2ebe5 |
| | Driver Version: 1.0 |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Hewlett Packard Enterprise
1701 E Mossy Oaks Rd
Spring
, TX
77389
|