 | ThinkSystem SD650 V3 (7D7M, Xeon SP Gen 5)
Network Server
Hewlett-Packard Company | 22 Jul 2024
153414 |
SUSE YES Certified for the following products:
Operating Systems:
| SUSE® Linux Enterprise Desktop 11 for AMD64 & Intel64 Service Pack 3 for SUSE® SLED 11 |
Virtual Machines (Guests OS):
| 3
SUSE® Linux Enterprise Server 15 for AMD64 & Intel64 |
|
SP:
Service Pack 6 for SUSE SLES 15 |
Arch:
64 |
Mode:
Fully Virtualized |
Product Description
For more information, please visit www.lenovo.com
Tested Configuration:
| Computer Type: | Compute Module |
| Mother Board Revision: | 06 |
| BIOS/uEFI: | UEFI: USE126G-4.10 (02/22/2024) |
| CPU: | 2 Intel
Xeon® Platinum 8592+ Processor 1.90 GHz |
| RAM: | 2 TB |
| Video Adapter: | ASPEED
AST2600 |
| Host Bus Adapter: | Samsung®
Non-Volatile memory controller (NVMe)
, NVMe |
| Hard Disk Drive: | Lenovo
ThinkSystem PM1733 Entry NVMe PCIe 4.0 x4 SSDs
, NVMe |
| Test Kit: | System Certification Kit 9.0.0-150500.103.1 |
Config Notes
- Install: System installed via network PXE UEFI boot; the OS was installed using the UEFI boot loader and system configuration.
- SR-IOV: System was tested using SR-IOV where a virtual network adapter was given to a SLES 15 SP5 FV guest. One of the Intel Ethernet Network Adapter X710-T4L adapters was used in this testing.
|
Referenced Bulletins
152213
Adapters and Drivers
| | | | | |
| ASPEED
AST2600 |
| | Driver Type: Video Driver | Driver Name: ast.ko.zst |
| | Driver Date: 12-Jun-2024 | Driver Size: 45011 |
| | Checksum: 171697309d0ce79d20252d08962ee209 |
|
| Mellanox®
Integrated MT27710 ConnectX®-4 Lx EN (Dual Port) 25GbE |
| | Driver Type: LAN Driver | Driver Name: mlx5_core.ko.zst |
| | Driver Date: 12-Jun-2024 | Driver Size: 1319123 |
| | Checksum: cc05292681b997dcb6acf58f269da9eb |
|
| Samsung®
Non-Volatile memory controller (NVMe) |
| | Driver Type: HBA Driver | Driver Name: nvme.ko.zst |
| | Driver Date: 12-Jun-2024 | Driver Size: 43741 |
| | Checksum: 1247b1054101dde0910e09fe6dbfa39d |
| | Driver Version: 1.0 |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Hewlett-Packard Company
Workstation Global Business Unit
Fort Collins
, CO
80528
Website: http://www.hp.com
|