 | ProLiant ML30 Gen11 (E-2488, 3.2 GHz, 8c)
Network Server
WIPRO LIMITED | 19 Dec 2023
152995 |
SUSE YES Certified for the following products:
Operating Systems:
| SUSE® Linux Enterprise Desktop 11 for x86 Service Pack 1 for SUSE® SLED 11 |
Virtual Machines (Guests OS):
| 2
SUSE® Linux Enterprise Server 15 for AMD64 & Intel64 |
|
SP:
Service Pack 4 for SUSE SLES 15 |
Arch:
64 |
Mode:
Fully Virtualized |
|
Windows Server 2019 |
|
Arch:
64 |
Mode:
Fully Virtualized |
Product Description
For more information please visit, https://www.hpe.com/us/en/servers.html
Tested Configuration:
| Computer Type: | Rack Mount |
| Mother Board Revision: | Gen11 |
| BIOS/uEFI: | UEFI: 1.40 (10/18/2023) |
| CPU: | Intel
Xeon® E-2488 Processor 3.20 GHz |
| RAM: | 128 GB |
| Ports and Bus Types: | 8 USB Ports |
| Video Adapter: | Matrox Graphics Inc.
G200eH3 |
| Host Bus Adapter: | HPE
MR216i-p Gen11 Storage Controller
, Serial SCSI (SAS) |
| Hard Disk Drive: | HPE
3.84TB SAS 12G MU SFF BC VS MV SSD
, Serial SCSI (SAS) |
| Test Kit: | System Certification Kit 8.8.1-150400.88.1 |
Config Notes
- The LAN driver used in testing is PLDP compliant and is available from: http://drivers.suse.com/driver-process/pub/update/Intel/sle10sp4/common/x86_64/
- Install: PXE Boot, OS Installed via Network.
|
Referenced Bulletins
137069
Adapters and Drivers
| | | | | |
| Matrox Graphics Inc.
G200eH3 |
| | Driver Type: Video Driver | Driver Name: mgag200.ko.zst |
| | Driver Date: 11-May-2022 | Driver Size: 17999 |
| | Checksum: 70e2e804042165de727265150a5ba2f5 |
|
| Intel
E810 Ethernet 10/25GbE 2P SFP28 Adapter |
| | Driver Type: LAN Driver | Driver Name: ice.ko.zst |
| | Driver Date: 12-May-2022 | Driver Size: 356152 |
| | Checksum: 42e9b28c2eaf1804d0707696c8fe655d |
|
| HPE
MR216i-p Gen11 Storage Controller |
| | Driver Type: HBA Driver | Driver Name: megaraid_sas.ko.zst |
| | Driver Date: 11-May-2022 | Driver Size: 91281 |
| | Checksum: 73fe8023764e189c76be50188530b557 |
| | Driver Version: 07.719.03.00-rc1 |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
WIPRO LIMITED
R. S No 49/5, Thiruvandar Koil
PONDICHERRY
, PU
605102
INDIA
Voice: +09884289426