 | Hitachi Advanced Server HA805 G3
Network Server
IEIT SYSTEMS Co., Ltd. | 23 Aug 2023
152613 |
SUSE YES Certified for the following products:
Operating Systems:
| SUSE® Linux Enterprise Server 15 for AMD64 & Intel64 Service Pack 6 for SUSE® SLES 15 |
Virtual Machines (Guests OS):
| 3
SUSE® Linux Enterprise Server 15 for AMD64 & Intel64 |
|
SP:
Service Pack 4 for SUSE SLES 15 |
Arch:
64 |
Mode:
Fully Virtualized |
|
Windows Server 2019 |
|
Arch:
64 |
Mode:
Fully Virtualized |
Product Description
For more information please visit, https://www.hitachivantara.com/
Tested Configuration:
| Computer Type: | Rack Mount |
| Mother Board Revision: | Gen11 |
| BIOS/uEFI: | UEFI: 1.12 (11/24/2022) |
| CPU: | AMD
EPYC™ 9654P 2.40 GHz |
| RAM: | 768 GB |
| Ports and Bus Types: | 5 USB Ports 2 PCI Express X16 |
| Video Adapter: | Matrox Graphics Inc.
G200eH3 |
| Host Bus Adapter: | HPE
MR216i-p Gen11 Storage Controller
, Serial SCSI (SAS) |
| Hard Disk Drive: | HPE
P40509-B21 7.68TB SAS SSD
, Serial SCSI (SAS) |
| Test Kit: | System Certification Kit 8.7.1-52.1 |
Config Notes
- Install: System installed via network PXE UEFI boot; the OS was installed using the UEFI boot loader and system configuration.
- Kdump (SLE15): the crash kernel reserved memory parameters were increased from the default to crashkernel=512M,high crashkernel=72M,low using YaST.
|
Adapters and Drivers
| | | | | |
| Matrox Graphics Inc.
G200eH3 |
| | Driver Type: Video Driver | Driver Name: mgag200.ko.zst |
| | Driver Date: 11-May-2022 | Driver Size: 17999 |
| | Checksum: 70e2e804042165de727265150a5ba2f5 |
|
| HPE
Ethernet 1Gb 4-port Base-T I350-T4 OCP3 Adapter |
| | Driver Type: LAN Driver | Driver Name: igb.ko.zst |
| | Driver Date: 11-May-2022 | Driver Size: 133614 |
| | Checksum: a02abff3db3974186b0bfb2a68639857 |
|
| HPE
MR216i-p Gen11 Storage Controller |
| | Driver Type: HBA Driver | Driver Name: megaraid_sas.ko.zst |
| | Driver Date: 11-May-2022 | Driver Size: 91281 |
| | Checksum: 73fe8023764e189c76be50188530b557 |
| | Driver Version: 07.719.03.00-rc1 |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
IEIT SYSTEMS Co., Ltd.
East side of Floor 9, No. 801, Caoshanling South Road, High-tech Zone, Jinan City, Shandong Province, PRC
Jinan
250101
CHINA
Website: https://www.ieisystem.com
|