 | ThinkSystem SR675 V3 (7D9Q, EPYC 9004)
Network Server
Huawei Technologies Co., Ltd | 31 May 2023
152120 |
SUSE YES Certified for the following products:
Operating Systems:
| SUSE® Linux Enterprise Server 11 for AMD64 & Intel64 Service Pack 4 for SUSE® SLES 11 |
Virtual Machines (Guests OS):
| 2
SUSE® Linux Enterprise Server 15 for AMD64 & Intel64 |
|
SP:
Service Pack 4 for SUSE SLES 15 |
Arch:
64 |
Mode:
Fully Virtualized |
| 2
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 |
|
SP:
Service Pack 5 for SUSE SLES 12 |
Arch:
64 |
Mode:
Fully Virtualized |
|
Windows Server 2022 |
|
Arch:
64 |
Mode:
Fully Virtualized |
Product Description
For more information about this system, please visit www.lenovo.com.
Tested Configuration:
| Computer Type: | Rack Mount |
| Mother Board Revision: | 03 |
| BIOS/uEFI: | UEFI: QGE111K - v1.30 (04/19/2023) |
| CPU: | 2 AMD
EPYC™ 9654 2.40 GHz |
| RAM: | 768 GB |
| Video Adapter: | ASPEED
AST2600 |
| Host Bus Adapter: | Micron Technology, Inc.
Non-Volatile memory controller (NVMe) Lenovo
ThinkSystem RAID 540-8i PCIe Gen4 12Gb SAS/SATA Adapter |
| Hard Disk Drive: | Lenovo
ThinkSystem M.2 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 NHS SSD 2 Lenovo
ThinkSystem 2.5-inch Intel S4620 1.92TB Mainstream SATA 6Gb Hot Swap SSD |
| Test Kit: | System Certification Kit 8.8.0-150400.74.3 |
Config Notes
- Hard Disk Configuration: RAID 0.
- Install: PXE Boot, OS Installed via Network.
- XEN Guests: VM Guests were configured with 1 GB of memory each, leaving more memory for the Xen host. In this configuration, if the guests are configured with more memory there is a possibility that network communication could be disrupted during times of heavy system load.
- VM Driver Pack: All FV guests were tested with PV drivers installed. The SLE10SP4 drivers are included with SLE10SP4. The Windows 2008 drivers are available from http://download.novell.com (VMDP-WIN-1.7_00.exe).
|
Adapters and Drivers
| | | | | |
| ASPEED
AST2600 |
| | Driver Type: Video Driver | Driver Name: ast.ko.zst |
| | Driver Date: 11-May-2022 | Driver Size: 31130 |
| | Checksum: 734c0cf8a6d7d153f61372e89322ca39 |
|
| Mellanox®
ConnectX-6 Lx 25GbE Dual-Port Ethernet SmartNIC (MT2894) |
| | Driver Type: LAN Driver | Driver Name: mlx5_core.ko.zst |
| | Driver Date: 11-May-2022 | Driver Size: 782670 |
| | Checksum: ccbb1c0799e3ade023de98c0322c7b0a |
|
| Micron Technology, Inc.
Non-Volatile memory controller (NVMe) |
| | Driver Type: HBA Driver | Driver Name: nvme.ko.zst |
| | Driver Date: 11-May-2022 | Driver Size: 28943 |
| | Checksum: a459b5d1051d7d147e095d396185ea0a |
| | Driver Version: 1.0 |
|
| Lenovo
ThinkSystem RAID 540-8i PCIe Gen4 12Gb SAS/SATA Adapter |
| | Driver Type: HBA Driver | Driver Name: megaraid_sas.ko.zst |
| | Driver Date: 11-May-2022 | Driver Size: 91281 |
| | Checksum: 73fe8023764e189c76be50188530b557 |
| | Driver Version: 07.719.03.00-rc1 |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Huawei Technologies Co., Ltd
Banxuegang Industrial Park Buji Longgang
Shenzhen
518129