 | SYS-120U-TNR
Network Server
Huawei Technologies Co., Ltd | 08 Jun 2021
150347 |
SUSE YES Certified for the following products:
Operating Systems:
|
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64
Service Pack 4 for SUSE® SLES 12 |
Product Description
For more information, please check Supermicro product web page at https://www.supermicro.com/en/products/system/Ultra/1U/SYS-120U-TNR .
Tested Configuration:
| Computer Type: | Rack Mount |
| Mother Board Revision: | 1.02 |
| BIOS/uEFI: | UEFI-Legacy: 1.0b (03/26/2021) |
| CPU: | 2 Intel
Xeon® Platinum 8380 Processor 2.30 GHz |
| RAM: | 512 GB |
| Ports and Bus Types: | 3 USB Ports 3 PCI Express X16 |
| Video Adapter: | ASPEED
AST2600 |
| Host Bus Adapter: | LSI Logic
MegaRAID SAS-3 3108
, Serial SCSI (SAS) |
| Hard Disk Drive: | 2 Micron Technology, Inc.
7300 MAX SSD 2.5-inch 3.2 TB NVMe U.2 (MTFDHBE3T2TDG)
, NVMe 2 KIOXIA
PM5-R Series, 7.6 TB, SAS SSD, (KPM51RUG7T68)
, Serial SCSI (SAS) |
| Test Kit: | System Certification Kit 8.5.0-29.4 |
Config Notes
- **NOTE**: Certified with HP preloaded version of SLED 11 SP2. Tested with preload image version 21.14.0.
- Power management: Hibernation / Suspend to Disk / ACPI S4 is NOT supported on this system.
- kdump: Crash kernel dump and capture does not function properly on this system and is therefore not supported.
|
Adapters and Drivers
| | | | | |
| ASPEED
AST2600 |
| | Driver Type: Video Driver | Driver Name: ast.ko |
| | Driver Date: 06-Jun-2020 | Driver Size: 115632 |
| | Checksum: f1fc1a718c1def157bd5b84ad0d9dbae |
|
| Intel
X540-AT2 10 Gigabit Ethernet Controller (Dual Port) |
| | Driver Type: LAN Driver | Driver Name: ixgbe.ko |
| | Driver Date: 06-Jun-2020 | Driver Size: 767560 |
| | Checksum: 8e262d9f66fbc816b26754e1b1945259 |
| | Driver Version: 5.1.0-k |
|
| LSI Logic
MegaRAID SAS-3 3108 |
| | Driver Type: HBA Driver | Driver Name: megaraid_sas.ko |
| | Driver Date: 07-Jun-2020 | Driver Size: 307352 |
| | Checksum: 6a8ab28719545a1f0f5b94fb61320d48 |
| | Driver Version: 07.713.01.00-rc1 |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Huawei Technologies Co., Ltd
Banxuegang Industrial Park Buji Longgang
Shenzhen
518129
CHINA
|