 | H3C UniServer B5700 G5
Network Server
Hewlett-Packard Company | 08 Jun 2021
150345 |
SUSE YES Certified for the following products:
Operating Systems:
|
SUSE® Linux Enterprise Desktop 11 for AMD64 & Intel64
Service Pack 2 for SUSE® SLED 11 |
Product Description
H3C UniServer B5700 G5
Tested Configuration:
| Computer Type: | Blade Module |
| Mother Board Revision: | 0231A111 |
| BIOS/uEFI: | UEFI: 5.24 (04/29/2021) |
| CPU: | 2 Intel
Xeon® Platinum 8352V Processor 2.10 GHz |
| RAM: | Host Platform: 384 GB, 64-bit VM Guests: 64 GB, Single Max VM 64-bit Guest Tested Memory: 256 GB |
| Ports and Bus Types: | PCI Express X8 3 USB Ports PCI Express X16 |
| Video Adapter: | ASPEED
AST2500 |
| Host Bus Adapter: | Samsung®
Non-Volatile memory controller (NVMe)
, NVMe |
| Hard Disk Drive: | Samsung®
PM963, 960GB, 2.5, NVMe, PCIe, SSD (MZQLW960HMJP)
, NVMe |
| Test Kit: | System Certification Kit 8.5.0-29.4 |
Config Notes
- Graphics: Video driver used in this configuration is PLDP-compliant. Video driver should be installed by adding http://download.nvidia.com/novell/sle11sp2 as an add-on product during OS install.
|
Adapters and Drivers
| | | | | |
| ASPEED
AST2500 |
| | Driver Type: Video Driver | Driver Name: ast.ko |
| | Driver Date: 06-Jun-2020 | Driver Size: 115632 |
| | Checksum: f1fc1a718c1def157bd5b84ad0d9dbae |
|
| Intel
Ethernet Controller I350-BT2 (Dual Port) |
| | Driver Type: LAN Driver | Driver Name: igb.ko |
| | Driver Date: 06-Jun-2020 | Driver Size: 496728 |
| | Checksum: bbf398d0be838fc838a89ffa888d4513 |
| | Driver Version: 5.6.0-k |
|
| | Driver Type: LAN Driver | Driver Name: igbvf.ko |
| | Driver Date: 06-Jun-2020 | Driver Size: 91648 |
| | Checksum: c3f471c2f7dbd65b4c98d5280e152139 |
| | Driver Version: 2.4.0-k |
|
| Samsung®
Non-Volatile memory controller (NVMe) |
| | Driver Type: HBA Driver | Driver Name: nvme.ko |
| | Driver Date: 06-Jun-2020 | Driver Size: 91280 |
| | Checksum: 7019e747c52a67a474517c09f9a2b763 |
| | Driver Version: 1.0 |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Hewlett-Packard Company
Workstation Global Business Unit
Fort Collins
, CO
80528
Website: http://www.hp.com
|