 | ThinkSystem ST650 V2 (7Z74, Xeon SP Gen 3)
Network Server
Fujitsu | 25 May 2021
150320 |
SUSE YES Certified for the following products:
Operating Systems:
SUSE® Linux Enterprise Desktop 11 for x86 Service Pack 3 for SUSE® SLED 11 |
Virtual Machines (Guests OS):
2
SUSE® Linux Enterprise Server 15 for AMD64 & Intel64 |
|
SP:
Service Pack 2 for SUSE SLES 15 |
Arch:
64 |
Mode:
Fully Virtualized |
2
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 |
|
SP:
Service Pack 5 for SUSE SLES 12 |
Arch:
64 |
Mode:
Fully Virtualized |
Windows Server 2019 |
|
Arch:
64 |
Mode:
Fully Virtualized |
Product Description
For more information about this system, please visit www.lenovo.com.
Tested Configuration:
Computer Type: | Tower |
Mother Board Revision: | 1.0 |
BIOS/uEFI: | UEFI: U8E109P-1.01 (04/08/2021) |
CPU: | 2 Intel
Xeon® Platinum 8352V Processor 2.10 GHz |
RAM: | Host: 512 GB, multiple VMs: 64 GB each, single max VM: 448 GB |
Persistent Memory: | 1TB, 8 Intel® Optane™ Persistent Memory 200 Series 128GB Modules |
Ports and Bus Types: | 4 PCI Express X16 4 PCI Express X8 PCI Express X4 6 USB Ports |
Video Adapter: | Matrox Graphics Inc.
G200 SE A (PCI) |
Host Bus Adapter: | Lenovo
ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
, Serial SCSI (SAS) |
Hard Disk Drive: | 4 Seagate®
Enterprise Performance SAS, 600GB, (ST600MP0006)
, Serial SCSI (SAS) |
Test Kit: | System Certification Kit 8.6.0-33.1 |
Config Notes
- Serial/USB/VGA port(s): provided through KVM connector console breakout cable which supplies one RS232 serial port, one VGA port and two USB ports, system also has one built-in USB port.
- Install: System installed via network PXE UEFI boot; the OS was installed using the UEFI boot loader and system configuration. Hard disk configuration: HDD - single SATA drive, M.2 boot drive - two SSD configured as a RAID 1. The "Device model" selected for the SLES guest virtual network adapter during testing was e1000, instead of the default virtio.
- SR-IOV: System was tested using SR-IOV where a virtual network adapter was given to the SLES 15 guest. One of the Intel Integrated Ethernet Connection X722 for 10GbE SFP+ adapters was used in this testing.
|
Adapters and Drivers
| | | | | |
Matrox Graphics Inc.
G200 SE A (PCI) |
| Driver Type: Video Driver | Driver Name: modesetting_drv.so |
| Driver Date: 18-Oct-2019 | Driver Size: 90480 |
| Checksum: 9877d59ad7917aeff72c31d506307e47 |
| Driver Version: 1.19.6 |
|
| Driver Type: Video Driver | Driver Name: swrast_dri.so |
| Driver Date: 18-Oct-2019 | Driver Size: 12525232 |
| Checksum: eb395f64921450dd329a614003936afd |
|
Broadcom®
NetXtreme® E-Series BCM57416 10GBASE-T PCIe 3.0 Ethernet Controller (Dual-Port) |
| Driver Type: LAN Driver | Driver Name: bnxt_en.ko |
| Driver Date: 08-Nov-2019 | Driver Size: 431968 |
| Checksum: e5f964d16bb61e985fcf6a68852ecc42 |
| Driver Version: 1.10.0 |
|
Lenovo
ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter |
| Driver Type: HBA Driver | Driver Name: megaraid_sas.ko |
| Driver Date: 09-Nov-2019 | Driver Size: 309256 |
| Checksum: a649376d8c32760e3d73ee1c44058ef7 |
| Driver Version: 07.707.51.00-rc1 |
|
The term SUSE "YES" Enterprise Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Fujitsu
Fujitsu Technology Solutions GmbH
TSP CLI E SW OSE
Bürgermeister-Ulrich-Strasse 100
Augsburg
86199
GERMANY
Voice: +49 (0)821 804-3321
|