 | PowerEdge M640
Network Server
Lenovo | 17 Aug 2018
147002 |
SUSE YES Certified for the following products:
Operating Systems:
| SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 with KVM Service Pack 2 for SUSE® SLES 12 |
Virtual Machines (Guests OS):
|
SUSE® Linux Enterprise Server 11 for AMD64 & Intel64 |
|
SP:
Service Pack 4 for SUSE SLES 11 |
Arch:
64 |
Mode:
Fully Virtualized |
|
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 |
|
SP:
Service Pack 3 for SUSE SLES 12 |
Arch:
64 |
Mode:
Fully Virtualized |
|
Windows Server 2012 R2 |
|
Arch:
64 |
Mode:
Fully Virtualized |
Product Description
The PowerEdge M640 is supported on both Dell PowerEdge VRTX and PowerEdge M1000e Blade Chassis. The Dell Shared PERC 8 card is located between the storage array and the power distribution board on the VRTX planar. The Dell Shared PERC H730P slot routes SAS to the nearby planar miniSAS connectors, which are used to internally cable SAS from the PERC to the SAS expander cards in the storage array. Please visit www.dell.com/vrtx for VRTX detail information. Please visit www.dell.com for more information.
Tested Configuration:
| Computer Type: | Blade Module |
| Mother Board Revision: | A00 |
| BIOS/uEFI: | UEFI: 1.4.8 (05/22/2018) |
| CPU: | 2 Intel
Xeon® Platinum 8176M Processor 2.10 GHz |
| RAM: | Host Platform: 2 TB, 64-bit VM Guests: 496 GB, Single Max VM 64-bit Guest Tested Memory: 1974 GB |
| Ports and Bus Types: | 2 USB Ports 2 PCI Express X8 2 PCI Express X4 |
| Video Adapter: | Matrox®
G200eW3 |
| Host Bus Adapter: | Dell
PowerEdge RAID Controller H730P Mini
, Serial SCSI (SAS) 2 Dell
Shared PERC 8
, Serial SCSI (SAS) |
| Hard Disk Drive: | 2 Seagate®
ST2000NX0453 SAS 2TB
, Serial SCSI (SAS) Toshiba
AL13SEB300
, Serial SCSI (SAS) |
| CD/DVD: | HLDS
GU60N
, USB |
| Test Kit: | System Certification Kit 8.1.0-83.2 |
Config Notes
- VMware guest OS installation information can be found at http://partnerweb.vmware.com/GOSIG/SLE_15.html.
- VMware recommends using the Open VM Tools redistributed by operating system vendors. For additional information, see knowledge base article 2073803 at http://kb.vmware.com/kb/2073803.
- VMware recommends using the paravirtual drivers contributed upstream and redistributed by operating system vendors. For additional information, see knowledge base article 2073804 at https://kb.vmware.com/kb/2073804.
- The VMware Memory Ballooning driver included in SLES 15 SP2 is auto loaded to improve the virtual machine memory performance.
- System certification testing was performed with a SLES 15 SP2 64-bit virtual machine configured with up to 128 CPUs and 6128 GB of memory.
|
Adapters and Drivers
| | | | | |
| Matrox®
G200eW3 |
| | Driver Type: Video Driver | Driver Name: mgag200.ko |
| | Driver Date: 31-May-2018 | Driver Size: 105288 |
| | Checksum: 1eae76e8c5bf871e23a8cf646aaf1ed6 |
|
| Intel
Gigabit 4P I350 bNDC (Quad Port) |
| | Driver Type: LAN Driver | Driver Name: igb.ko |
| | Driver Date: 31-May-2018 | Driver Size: 489024 |
| | Checksum: d5232654a1debc91e634dcdcdf5d1fc8 |
| | Driver Version: 5.4.0-k |
|
| | Driver Type: LAN Driver | Driver Name: igbvf.ko |
| | Driver Date: 31-May-2018 | Driver Size: 91176 |
| | Checksum: 0e086f13fa88839bfea7aef53fc5a5e5 |
| | Driver Version: 2.4.0-k |
|
| Dell
PowerEdge RAID Controller H730P Mini |
| | Driver Type: HBA Driver | Driver Name: megaraid_sas.ko |
| | Driver Date: 31-May-2018 | Driver Size: 288872 |
| | Checksum: 05a11c19ea5020998382f29c3ae31971 |
| | Driver Version: 07.704.04.00-rc1 |
|
| 2 Dell
Shared PERC 8 |
| | Driver Type: HBA Driver | Driver Name: megaraid_sas.ko |
| | Driver Date: 31-May-2018 | Driver Size: 288872 |
| | Checksum: 05a11c19ea5020998382f29c3ae31971 |
| | Driver Version: 07.704.04.00-rc1 |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.