 | G560
Network Server
IBM | 18 Dec 2017
146403 |
SUSE YES Certified for the following products:
Operating Systems:
| SUSE® Linux Enterprise Server for z Systems 15 Service Pack 1 for SUSE® SLES 15 |
Product Description
http://e.huawei.com/en/products/cloud-computing-dc/servers/g-series/g560
Tested Configuration:
| Computer Type: | Blade Module |
| Mother Board Revision: | V100R001 |
| BIOS/uEFI: | Legacy: 3.76 (09/21/2017) |
| CPU: | 2 Intel
Xeon® Processor E5-2630 v4 2.20 GHz |
| RAM: | 128 GB |
| Ports and Bus Types: | 6 PCI Express X4 12 PCI Express X16 USB Ports |
| Video Adapter: | Silicon Motion, Inc.
SM750 |
| Host Bus Adapter: | LSI Logic
MegaRAID SAS-3 3108
, Serial SCSI (SAS) |
| Hard Disk Drive: | Seagate®
ST300MM0026
, Serial ATA (SATA) |
| Test Kit: | System Certification Kit 7.7.0-25.2 |
Config Notes
- Install: System installed via network PXE UEFI boot; the OS was installed using the UEFI boot loader and system configuration. Hard Drive Configuration: RAID 5 w/hot swap drive. Xen Hypervisor: the hypervisor was booted with following additional parameters: dom0_mem=10G dom0_max_vcpus=4.
- Kdump: the crash kernel reserved memory parameters were increased from the default to "crashkernel=119M,high crashkernel=122M,low" using YaST.
- VM Driver Pack: All guests were tested with PV drivers installed. The SLES drivers are included with the OS. The Windows 2012 R2 drivers are available from https://download.suse.com/ (VMDP-WIN-2.3.exe).
- PCI Network Pass-Through: System was tested using PCI pass-through where one of the host network adapters was given to the one of the SLES 12 guests. The IBM x3750 M4 Dual port 10 GB SFP+ Ethernet adapter was used for this testing.
|
Adapters and Drivers
| | | | | |
| Silicon Motion, Inc.
SM750 |
| | Driver Type: Video Driver | Driver Name: modesetting_drv.so |
| | Driver Date: 15-Oct-2016 | Driver Size: 73936 |
| | Checksum: 9543c0db503bf1f52b6304492e605509 |
| | Driver Version: 1.18.3 |
|
| Intel
Ethernet Server Adapter I350-T2 (Dual Port) |
| | Driver Type: LAN Driver | Driver Name: igb.ko |
| | Driver Date: 25-Oct-2016 | Driver Size: 351071 |
| | Checksum: b8dee794a1123732c7ba8475033703e3 |
| | Driver Version: 5.3.0-k |
|
| LSI Logic
MegaRAID SAS-3 3108 |
| | Driver Type: HBA Driver | Driver Name: megaraid_sas.ko |
| | Driver Date: 25-Oct-2016 | Driver Size: 216703 |
| | Checksum: 43d97f95db88b476471065c1667d0589 |
| | Driver Version: 06.810.09.00-rc1 |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
IBM
For support regarding this specific configuration, please visit:
www.ibm.com
|