 | Compute Blade 520X B2 LPAR
Network Server
Intel Corporation | 27 Oct 2017
146133 |
SUSE YES Certified for the following products:
Operating Systems:
SUSE® Linux Enterprise Server 11 for AMD64 & Intel64 with XEN Service Pack 3 for SUSE® SLES 11 |
Virtual Machines (Guests OS):
3
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 |
|
SP:
Service Pack 2 for SUSE SLES 12 |
Arch:
64 |
Mode:
Fully Virtualized |
Product Description
The Hitachi logical partitioning manager (LPAR) firmware version is 02. Please see http://www.hds.com/products/compute-blade/compute-blade-2500.html.
Tested Configuration:
Computer Type: | Virtual Machine |
Mother Board Revision: | 00MN607 |
BIOS/uEFI: | UEFI: 09-48 (02/07/2017) |
CPU: | 8 Intel
Xeon® Processor E7-8880 v3 2.30 GHz |
RAM: | Host Platform: 6 TB, 64-bit VM Guests: 1 TB, Single Max VM 64-bit Guest Tested Memory: 4 TB |
Ports and Bus Types: | 3 USB Ports |
Video Adapter: | Hitachi
Virtual VGA compatible controller |
Host Bus Adapter: | Hitachi
16Gb 2-port Fibre Channel adapter
, FibreChannel |
Storage Area Network (SAN) Device: | Hitachi Data Systems
Hitachi Unified Storage VM (HUS VM) |
Test Kit: | System Certification Kit 7.7.0-25.1 |
Config Notes
- Install: The SLES install was performed using a virtual DVD device.
|
Adapters and Drivers
| | | | | |
Hitachi
Virtual VGA compatible controller |
| Driver Type: Video Driver | Driver Name: modesetting_drv.so |
| Driver Date: 15-Oct-2016 | Driver Size: 73936 |
| Checksum: 9543c0db503bf1f52b6304492e605509 |
| Driver Version: 1.18.3 |
|
Intel
Ethernet Server Adapter X520-2 (Dual Port) |
| Driver Type: LAN Driver | Driver Name: ixgbe.ko |
| Driver Date: 22-Feb-2017 | Driver Size: 9746224 |
| Checksum: 537df3626588b014553bde4022ff5bbc |
| Driver Version: 4.4.6-h1 |
|
Hitachi
16Gb 2-port Fibre Channel adapter |
| Driver Type: HBA Driver | Driver Name: hfcldd.ko |
| Driver Date: 28-Jul-2017 | Driver Size: 27607888 |
| Checksum: 481ed8ad2b44de6826babb351887ddc7 |
| Driver Version: 4.12.21.4284 |
|
The term SUSE "YES" Enterprise Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Intel Corporation
Columbia Design Center
100 Center Point Circle, Suite 200
Columbia
, SC
29210
Voice: 803-216-2100
Website: www.intel.com
|