 | ProLiant XL230k Gen10 (Apollo K6000) 2.10 GHz Twenty-Eight Core
Network Server
Fujitsu | 13 Jul 2017
145725 |
SUSE YES Certified for the following products:
Operating Systems:
SUSE® Linux Enterprise Server 15 for AMD64 & Intel64 |
Virtual Machines (Guests OS):
SUSE® Linux Enterprise Server 11 for x86 |
|
SP:
Service Pack 4 for SUSE SLES 11 |
Arch:
32pae |
Mode:
Fully Virtualized |
SUSE® Linux Enterprise Server 11 for AMD64 & Intel64 |
|
SP:
Service Pack 4 for SUSE SLES 11 |
Arch:
64 |
Mode:
Fully Virtualized |
Windows Server 2012 R2 |
|
Arch:
64 |
Mode:
Fully Virtualized |
Product Description
For more information, please visit https://www.hpe.com/us/en/servers.html
Tested Configuration:
Computer Type: | Rack Mount |
Mother Board Revision: | Gen10 |
BIOS/uEFI: | UEFI: 1.0 (06/02/2017) |
CPU: | 2 Intel
Xeon® Platinum 8176 Processor 2.10 GHz |
RAM: | 128 GB |
Ports and Bus Types: | 3 USB Ports Serial 2 PCI Express X16 |
Video Adapter: | Matrox®
G200eH |
Host Bus Adapter: | Intel
C621 Chipset
, Serial ATA (SATA) |
Hard Disk Drive: | HP
MM1000GBKAL
, Serial ATA (SATA) |
Test Kit: | System Certification Kit 7.6.0-53.1 |
Config Notes
- The s-Par® firmware version is 4.3.403.2947 (2016-04-13)
- Install: System booted to DVD, and OS installed via network.
- All listed drivers are SUSE SolidDriver compliant and are delivered as part of the Forward! by Unisys™ (PEPP) product
|
Adapters and Drivers
| | | | | |
Matrox®
G200eH |
| Driver Type: Video Driver | Driver Name: libfb.so |
| Driver Date: 26-May-2015 | Driver Size: 138752 |
| Checksum: ed7cf2d9c60c06fca06019e821c4b4eb |
| Driver Version: 1.0.0 |
|
HPE
Ethernet 10Gb 2-port 568i Adapter |
| Driver Type: LAN Driver | Driver Name: i40e.ko |
| Driver Date: 19-May-2017 | Driver Size: 6506753 |
| Checksum: 80eb9b69a4019ce7356ef677495499f3 |
| Driver Version: 2.0.23 |
|
Intel
C621 Chipset |
| Driver Type: HBA Driver | Driver Name: ahci.ko |
| Driver Date: 31-Mar-2017 | Driver Size: 60375 |
| Checksum: 3faa30ce4daa49f046f234be98d5b1e4 |
| Driver Version: 3.0 |
|
The term SUSE "YES" Enterprise Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Fujitsu
Fujitsu Technology Solutions GmbH
Mies-van-der-Rohe-Strasse 8
München
80807
GERMANY
|