|
 | ThinkServer RD550 (E5-2600 v3)
Network Server
Positivo Tecnologia S.A. | 12 Jan 2017
145299 |
SUSE YES Certified for the following products:
Operating Systems:
| SUSE® Linux Enterprise Desktop 12 for AMD64 & Intel64 Service Pack 3 for SUSE® SLED 12 |
Virtual Machines (Guests OS):
|
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 |
|
SP:
Service Pack 2 for SUSE SLES 12 |
Arch:
64 |
Mode:
Paravirtualized |
|
SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 |
|
SP:
Service Pack 2 for SUSE SLES 12 |
Arch:
64 |
Mode:
Fully Virtualized |
|
SUSE® Linux Enterprise Server 11 for x86 |
|
SP:
Service Pack 4 for SUSE SLES 11 |
Arch:
32 |
Mode:
Paravirtualized |
|
SUSE® Linux Enterprise Server 11 for AMD64 & Intel64 |
|
SP:
Service Pack 4 for SUSE SLES 11 |
Arch:
64 |
Mode:
Fully Virtualized |
|
Windows Server 2016 |
|
Arch:
64 |
Mode:
Fully Virtualized |
Product Description
For more information, please visit www.lenovo.com.
Tested Configuration:
| Computer Type: | Rack Mount |
| Mother Board Revision: | RAVEN MB Rev 1.1 |
| BIOS/uEFI: | UEFI: PB1TS360 v3.60.0 (03/09/2016) |
| CPU: | 2 Intel
Xeon® Processor E5-2698 v3 2.30 GHz |
| RAM: | Host platform: 128 GB, multiple 64-bit VM guests: 24 GB, 32-bit guest: 8 GB, Windows 2016 VM guest: 16 GB, single max VM guest: 112 GB |
| Ports and Bus Types: | 4 USB Ports 2 PCI Express X16 2 PCI Express X8 |
| Video Adapter: | ASPEED
AST2400 |
| Host Bus Adapter: | Lenovo
Thinkserver RAID 510i AnyRAID
, Serial SCSI (SAS) |
| Hard Disk Drive: | 2 Hitachi
HUS156060VLS600
, Serial SCSI (SAS) |
| Test Kit: | System Certification Kit 7.6.0-44.1 |
Config Notes
- System certification testing was performed with a SLES 15 SP7 64-bit virtual machine installed on UEFI firmware with Secure Boot enabled and configured with up to 960 CPUs and 16384 GB of memory.
- Broadcom recommends using the Open VM Tools redistributed by operating system vendors. For additional information, see knowledge base article 313456 at https://knowledge.broadcom.com/external/article?articleNumber=313456.
- Broadcom recommends using the paravirtual drivers contributed upstream and redistributed by operating system vendors . For additional information, see knowledge base article 306577 at https://knowledge.broadcom.com/external/article?articleNumber=306577.
- The VMware Memory Ballooning driver included in SLES 15 SP7 is auto loaded to improve the virtual machine memory performance.
- VMware guest OS installation information can be found at: http://partnerweb.vmware.com/GOSIG/SLE_15.html.
|
Adapters and Drivers
| | | | | |
| ASPEED
AST2400 |
| | Driver Type: Video Driver | Driver Name: ast.ko |
| | Driver Date: 25-Oct-2016 | Driver Size: 105903 |
| | Checksum: fa330b167f8c09c2d71c4e89b516b418 |
|
| | Driver Type: Video Driver | Driver Name: ast_drv.so |
| | Driver Date: 14-Oct-2016 | Driver Size: 114288 |
| | Checksum: d8354d50377cbbdc635b0a299a0f5d38 |
| | Driver Version: 1.1.5 |
|
| | Driver Type: Video Driver | Driver Name: drm.ko |
| | Driver Date: 25-Oct-2016 | Driver Size: 628983 |
| | Checksum: 917601927ed3ac76295bd6a5c5521679 |
|
| Intel
Ethernet Server Adapter I350-T2 (Dual Port) |
| | Driver Type: LAN Driver | Driver Name: igb.ko |
| | Driver Date: 25-Oct-2016 | Driver Size: 351071 |
| | Checksum: b8dee794a1123732c7ba8475033703e3 |
| | Driver Version: 5.3.0-k |
|
| Lenovo
Thinkserver RAID 510i AnyRAID |
| | Driver Type: HBA Driver | Driver Name: megaraid_sas.ko |
| | Driver Date: 25-Oct-2016 | Driver Size: 216703 |
| | Checksum: 43d97f95db88b476471065c1667d0589 |
| | Driver Version: 06.810.09.00-rc1 |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Positivo Tecnologia S.A.
Rua Javari, 1255 Distrito Industrial
Manaus
, AM
CEP 69075-110
BRAZIL
|