 | 5288 V3
Network Server
Oracle America Inc. | 06 Jul 2015
143384 |
SUSE YES Certified for the following products:
Operating Systems:
| SUSE® Linux Enterprise Server 11 for AMD64 & Intel64 Service Pack 3 for SUSE® SLES 11 |
Product Description
http://e.huawei.com/en/products/cloud-computing-dc/servers/rh-series/5288-v3
Tested Configuration:
| Computer Type: | Rack Mount |
| Mother Board Revision: | V100R003 |
| BIOS/uEFI: | uEFI-Legacy: 1.17 (09/03/2014) |
| CPU: | 2 Intel
Xeon® Processor E5-2650L v3 1.80 GHz |
| RAM: | 16 GB |
| Ports and Bus Types: | 5 USB Ports 2 PCI Express X16 6 PCI Express X8 |
| Video Adapter: | Silicon Motion, Inc.
SM750 |
| Host Bus Adapter: | LSI Logic
SAS 3008
, Serial SCSI (SAS) |
| Hard Disk Drive: | Seagate®
ST9500530NS
, Serial SCSI (SAS) |
| Test Kit: | System Certification Kit 7.2.0-5.10 |
Config Notes
- Xen Hypervisor: the hypervisor was booted with following additional parameters: dom0_mem=10G dom0_max_vcpus=10.
- Tested as a 2-node scalable partition with 8 Compute Books. Hard disk configuration: RAID 0 and RAID 1.
- Maintenance update: SLES 11 SP3 Xen maintenance update 8973 and kernel update 9329 (x86-64) are required and were installed during certification testing.
- VM Driver Pack: All guests were tested with PV drivers installed. The SLES 11 SP3 drivers are included with the OS. The Windows 2012 R2 drivers are available from http://download.novell.com (VMDP-WIN-2.1.exe).
- SUSE Driver Kit: The ibm_x6-sle11sp3-x86_64 driver kit is SUSE SolidDriver Program compliant. The driver kit was installed during the SLES install process as an initial bootable iso image. This driver must be downloaded and installed before the SLES install. To obtain the driver go to: http://drivers.suse.com/ibm/IBM-X6/sle11-sp3/install-readme.html.
- Install: System installed using an external USB DVD drive; the OS was installed from DVD using the UEFI boot loader and elilo system configuration.
- Kdump: the crash kernel reserved memory parameter in the elilo.conf file was changed from 128 to 256 (crashkernel:512M-:256M) for kdump to function correctly.
- PCI Network Pass-Through: System was tested using PCI pass-through where two of the host network adapters were given, one each, to the FV SLES 11 SP3 i586 and FV SLES 11 SP3 x86-64 guests. Two of the Intel® I350-T4 ML2 Quad Port GbE Adapters was used during this testing.
|
Referenced Bulletins
141670
Adapters and Drivers
| | | | | |
| Silicon Motion, Inc.
SM750 |
| | Driver Type: Video Driver | Driver Name: fbdev_drv.so |
| | Driver Date: 09-Mar-2013 | Driver Size: 23688 |
| | Checksum: 3d2a3bede51296525d33a2e8c5650f56 |
| | Driver Version: 0.4.1 |
|
| 4 Broadcom®
BCM5719 PCI Express® Gigabit Ethernet |
| | Driver Type: LAN Driver | Driver Name: tg3.ko |
| | Driver Date: 14-Jun-2013 | Driver Size: 242863 |
| | Checksum: f89cba187ed6394b55c6f3545b981f06 |
| | Driver Version: 3.129 |
|
| LSI Logic
SAS 3008 |
| | Driver Type: HBA Driver | Driver Name: mpt3sas.ko |
| | Driver Date: 14-Jun-2013 | Driver Size: 341023 |
| | Checksum: 202b47b7f9a9596a69269e6a59882729 |
| | Driver Version: 01.100.01.00 |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Oracle America Inc.
500 Oracle Parkway
Redwood Shores
, CA
94065
Website: www.Oracle.com
|