|
 | CB50-G20
Network Server
Fujitsu | 15 Jun 2015
143290 |
SUSE YES Certified for the following products:
Operating Systems:
| SUSE® LINUX Enterprise Server 10 for x86 Service Pack 2 for SUSE® SLES 10 |
Product Description
For more information, please visit www.sugon.com
Tested Configuration:
| Computer Type: | Blade Module |
| Mother Board Revision: | 60G16B |
| BIOS/uEFI: | UEFI-Legacy: V0.17 (05/27/2015) |
| CPU: | 2 Intel
Xeon® Processor E5-2680 v3 2.50 GHz |
| RAM: | 128 GB |
| Ports and Bus Types: | 2 USB Ports PCI Express X8 2 PCI Express X16 |
| Video Adapter: | ASPEED
AST2400 |
| Host Bus Adapter: | LSI Logic
MegaRAID SAS-3 3008
, Serial SCSI (SAS) |
| Hard Disk Drive: | Seagate®
ST9900805SS
, Serial SCSI (SAS) |
| Test Kit: | System Certification Kit 7.3.0-113.1 |
Config Notes
- Install: System installed using PXE network install; the OS was installed using the UEFI boot loader and system configuration. Disk configuration: RAID 0. Kdump (SLE12SP4): the crash kernel reserved memory parameters were increased from the default to crashkernel=243M,high crashkernel=132M,low using YaST.
- Serial/USB/VGA port(s): provided through a KVM connector console breakout cable which supplies one RS232 serial port, one VGA port and two USB ports. As noted in the Tested Configuration above, the system also has one internal USB port.
- SR-IOV: System was tested using SR-IOV where a virtual network adapter was given to a SLES 12 guest. One of the Intel Ethernet Connection X722 for 10GbE SFP+ adapters was used in this testing.
|
Adapters and Drivers
| | | | | |
| ASPEED
AST2400 |
| | Driver Type: Video Driver | Driver Name: ast_drv.so |
| | Driver Date: 23-Aug-2014 | Driver Size: 105640 |
| | Checksum: 81262913bc140c6bfbe50e5011f4a1a1 |
| | Driver Version: 1.0.1 |
|
| | Driver Type: Video Driver | Driver Name: drm.ko |
| | Driver Date: 08-Oct-2014 | Driver Size: 523055 |
| | Checksum: 24f1502cad78a842cfa8f8c86ed2de25 |
|
| | Driver Type: Video Driver | Driver Name: ast.ko |
| | Driver Date: 09-Oct-2014 | Driver Size: 109279 |
| | Checksum: aa0d73dab0e4468dd23c2349ca6be90c |
|
| Intel
Ethernet Server Adapter I350-T2 (Dual Port) |
| | Driver Type: LAN Driver | Driver Name: igb.ko |
| | Driver Date: 29-Sep-2014 | Driver Size: 319895 |
| | Checksum: 5dc831ebe3c0bfe03571c08dedd554dc |
| | Driver Version: 5.0.5-k |
|
| LSI Logic
MegaRAID SAS-3 3008 |
| | Driver Type: HBA Driver | Driver Name: mpt3sas.ko |
| | Driver Date: 08-Oct-2014 | Driver Size: 355191 |
| | Checksum: 96c97ecc814b1db180773efee1399680 |
| | Driver Version: 04.100.00.00 |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Fujitsu
Fujitsu Technology Solutions GmbH
FTS TSP ST
Heinz-Nixdorf-Ring 1
Paderborn
33106
GERMANY
|