| UCS B260 M4
Network Server
VMware, Inc. | 15 May 2014
141488 |
SUSE YES Certified for the following products:
Product Description
Cisco UCS B260 M4; http://www.cisco.com/c/en/us/products
Tested Configuration:
| Computer Type: | Blade Module |
| Mother Board Revision: | 4.0 |
| BIOS/uEFI: | UEFI: EXM4-1.2.2.2.0.042820141805 |
| CPU: | 2 Intel
Xeon® Processor E7-4880 v2 2.50 GHz |
| RAM: | 256 GB |
| Ports and Bus Types: | USB Ports |
| Video Adapter: | Matrox®
MGA G200e |
| Host Bus Adapter: | LSI Logic
MegaRAID SAS-3 3008
, Serial SCSI (SAS) Cisco
UCS VIC 1280 (HBA)
, FibreChannel |
| Hard Disk Drive: | Unigen
UGB30SDC16H0 CompactFlash Card
, USB Seagate®
Savvio® (ST9146852SS) 15K.2 6-Gbps 146-GB Hard Drive
, Serial SCSI (SAS) |
| Storage Area Network (SAN) Device: | EMC
Symmetrix VMAX |
| Test Kit: | System Certification Kit 7.2.0-5.10 |
Config Notes
- SLES 12 SP2 guest was installed on UEFI firmware with Secure Boot enabled.
- VMware recommends to install deployPkg with open-vm-tools if creating a Template http://kb.vmware.com/kb/2075048.
- Virtual machine guest: System certification testing was performed with a single max virtual machine configured with up to 6128 GB of memory on a SLES 12 SP2 x86-64 guest.
- Virtual machine guest: System certification testing was performed with a SLES 12 SP2 64-bit virtual machine configured with up to 128 CPUs.
- VMware recommends using the Open VM Tools redistributed by the operating system vendors. For additional information, see knowledge base article 2073803 at http://kb.vmware.com/kb/2073803. VMware guest OS installation information can be found at: http://partnerweb.vmware.com/GOSIG/SLE_12.html
- The VMware Memory Ballooning driver included in SLES 12 SP2 is auto loaded to improve the virtual machine memory performance.
|
Adapters and Drivers
| | | | | |
| Matrox®
MGA G200e |
| | Driver Type: Video Driver | Driver Name: mga_drv.so |
| | Driver Date: 30-Mar-2013 | Driver Size: 190720 |
| | Checksum: cbbe7ba695cb37835f3c7d4e79ec43c5 |
| | Driver Version: 1.4.11 |
|
| Cisco
UCS VIC 1280 (NIC) |
| | Driver Type: LAN Driver | Driver Name: enic.ko |
| | Driver Date: 02-Jul-2013 | Driver Size: 108559 |
| | Checksum: 7c8a72f84dbb6750642d0cd2d94f476f |
| | Driver Version: 2.1.1.39 |
|
| LSI Logic
MegaRAID SAS-3 3008 |
| | Driver Type: HBA Driver | Driver Name: megaraid_sas.ko |
| | Driver Date: 21-Nov-2013 | Driver Size: 1464179 |
| | Checksum: 1899cabcb7a2678e11c480d22a6663b3 |
| | Driver Version: 06.602.03.00 |
|
| Cisco
UCS VIC 1280 (HBA) |
| | Driver Type: HBA Driver | Driver Name: fnic.ko |
| | Driver Date: 02-Jul-2013 | Driver Size: 163231 |
| | Checksum: 0cdca3f442cc3a63c4da268ea8a21684 |
| | Driver Version: 1.5.0.22 |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
VMware, Inc.
3401 Hillview Ave
Palo Alto
, CA
94304
Voice: 1-650-427-5000
Toll Free: 1-877-486-9273
Fax: 650-427-5001