 | HUAWEI T3500 G3
Network Server
IBM | 11 Sep 2012
138537 |
SUSE YES Certified for the following products:
Operating Systems:
| SUSE® Linux Enterprise Server 11 for AMD64 & Intel64 with KVM Service Pack 3 for SUSE® SLES 11 |
Product Description
http://enterprise.huawei.com/en/products/itapp/server/rh-series-rack-servers/hw-149300.htm
Tested Configuration:
| Computer Type: | Rack Mount |
| Mother Board Revision: | v100R011 |
| BIOS/uEFI: | STG20610 |
| CPU: | 2 Intel
Xeon® Processor E5-2450L 1.80 GHz |
| RAM: | 32 GB |
| Ports and Bus Types: | 4 PCI Express X8 PCI Express X4 |
| Video Adapter: | ASPEED
AST1100 |
| Host Bus Adapter: | LSI Logic
LSISAS2008
, Serial SCSI (SAS) |
| Hard Disk Drive: | Seagate®
Savvio® 15K.3, 2.5-inch 300 GB 15K 6Gb/s SAS (ST9300653SS)
, Serial SCSI (SAS) |
| Test Kit: | System Certification Kit 7.1.0-33.2 |
Config Notes
- Hard Disk Configuration: RAID 0 and RAID 1.
- PCI Network Pass-Through: System was tested using PCI pass-through where the network adapter was given to the SLES 11 SP3 x86-64 guest. One of the embedded Intel Ethernet Controller I350-AM4 adapters was used in this testing.
- VM Driver Pack: All FV guests were tested with PV drivers installed. The SLES 11 SP3 drivers are included with the OS. The Windows 2012 drivers are available from http://download.novell.com (VMDP-WIN-2.1.exe).
|
Adapters and Drivers
| | | | | |
| ASPEED
AST1100 |
| | Driver Type: Video Driver | Driver Name: swrast_dri.so |
| | Driver Date: 09-May-2010 | Driver Size: 2380528 |
| |
|
| | Driver Type: Video Driver | Driver Name: ast_drv.so |
| | Driver Date: 12-Apr-2010 | Driver Size: 60848 |
| | Checksum: 8e4e7eec0ef3525ae067564d6cccbe56 |
|
| 4 Broadcom®
BCM5716 NetXtreme II Gigabit Ethernet Adapter |
| | Driver Type: LAN Driver | Driver Name: bnx2.ko |
| | Driver Date: 20-May-2010 | Driver Size: 118712 |
| | Checksum: 310235af077333686b82d4999c00a232 |
|
| LSI Logic
LSISAS2008 |
| | Driver Type: HBA Driver | Driver Name: mpt2sas.ko |
| | Driver Date: 20-May-2010 | Driver Size: 216504 |
| | Checksum: 4f4d893c3e89e8f971c1ed835b470a5c |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
IBM
For support regarding this specific configuration, please visit:
www.ibm.com
|