 | ProLiant BL460c G7 2.93 GHz Six Core
Network Server
Inspur Corporation | 18 Oct 2010
133935 |
SUSE YES Certified for the following products:
Operating Systems:
| SUSE® Linux Enterprise Server 11 for AMD64 & Intel64 Service Pack 4 for SUSE® SLES 11 |
Virtual Machines (Guests OS):
|
SUSE® LINUX Enterprise Server 10 for AMD64 & Intel64 |
|
SP:
Service Pack 3 for SLES 10 |
Arch:
64 |
Mode:
Fully Virtualized |
|
SUSE® LINUX Enterprise Server 10 for x86 |
|
SP:
Service Pack 3 for SLES 10 |
Arch:
32pae |
Mode:
Paravirtualized |
|
Windows 2003 Server R2 |
|
SP:
Service Pack 2 for Windows 2003 |
Arch:
32 |
Mode:
Fully Virtualized |
Product Description
For more information, please visit http://www.hp.com/go/proliantlinux
Tested Configuration:
| Computer Type: | Blade Module |
| Mother Board Revision: | G7 |
| BIOS/uEFI: | I27 - 08/16/2010 |
| CPU: | 2 Intel
Xeon® Processor X5670 2.93 GHz |
| RAM: | 192 GB |
| Ports and Bus Types: | 2 PCI Express X8 USB Ports Serial |
| Video Adapter: | Matrox®
G200eH |
| Host Bus Adapter: | HP
Smart Array P410i Controller
, Serial SCSI (SAS) |
| Hard Disk Drive: | HP
DG072A3315 72GB SAS 10K
, Serial SCSI (SAS) |
| Floppy Type: | NONE |
| Test Kit: | System Certification Kit 6.6.0-34.1 |
Config Notes
- Install: System installed using PXE network install; the OS was installed using the UEFI boot loader and system configuration. Disk configuration: HDD two disk RAID 0 and M.2 boot device with two SSD configured as RAID 0. Xen Hypervisor: the hypervisor was booted with and requires the following additional load parameters: dom0_mem:16G dom0_max_vcpus:16.
- Kdump (SLE15): the crash kernel reserved memory parameters were increased from the default to crashkernel=231M,high crashkernel=122M,low using YaST.
- VM Driver Pack: All guests were tested with PV drivers installed. The SLES drivers are included with the OS. The Windows Server 2016 drivers are available from http://download.suse.com (VMDP-WIN-2.5.exe).
- SR-IOV: System was tested using SR-IOV where a virtual network adapter was given to the SLES 15 FV guest. One of the internal X550-T2 10GBase-T adapters was used in this testing.
|
Adapters and Drivers
| | | | | |
| Matrox®
G200eH |
| | Driver Type: Video Driver | Driver Name: vesa_drv.so |
| | Driver Date: 05-Sep-2009 | Driver Size: 28072 |
| | Checksum: 0924b0f658357f94e06521969e66bc6b |
|
| HP
NC553i Dual Port 10Gb Network Adapter |
| | Driver Type: LAN Driver | Driver Name: be2net.ko |
| | Driver Date: 15-Jun-2010 | Driver Size: 83953 |
| | Checksum: 55701f5be64f98f2443d7f83ffc62674 |
|
| HP
Smart Array P410i Controller |
| | Driver Type: HBA Driver | Driver Name: cciss.ko |
| | Driver Date: 05-Sep-2009 | Driver Size: 105096 |
| | Checksum: a0a7d8772a21aee9b587f4be10f068b9 |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Inspur Corporation
Building C. NO.2
Xinxi Road
Shangdi, Haidian District
Beijing
100080
CHINA
|