|
 | ProLiant ML370 G6 3.33GHz Six Core
Network Server
Lenovo | 21 Jul 2010
133096 |
SUSE YES Certified for the following products:
Operating Systems:
| SUSE® Linux Enterprise Server 12 for AMD64 & Intel64 with KVM |
Product Description
For more information,please visit http://www.hp.com/go/proliantlinux.
Tested Configuration:
| Computer Type: | Rack Mount |
| Mother Board Revision: | G6 |
| BIOS/uEFI: | P63-03/30/2010 |
| CPU: | 2 Intel
Xeon® Processor X5680 3.33 GHz |
| RAM: | 16 GB |
| Ports and Bus Types: | 6 PCI Express X4 2 PCI Express X8 2 PCI Express X16 Serial 5 USB Ports |
| Video Adapter: | ATI
Integrated RN50 |
| Host Bus Adapter: | HP
HP Smart Array P410i Controller
, Serial SCSI (SAS) |
| Hard Disk Drive: | HP
DG146ABAB4 146GB SAS 10K
, Serial SCSI (SAS) HP
EG0300FARTT
, Serial SCSI (SAS) |
| Floppy Type: | NONE |
| Test Kit: | System Certification Kit 6.5.0-0.30 |
Config Notes
- Install: System installed using PXE network install; the OS was installed using the UEFI boot loader and system configuration. Disk configuration: HDD single disk RAID 0 and M.2 boot device configured with two SSDs in RAID 1. Kdump (SLE15): the crash kernel reserved memory parameters were increased from the default to crashkernel=279M,high crashkernel=172M,low using YaST.
- SR-IOV: System was tested using SR-IOV where a virtual network adapter was given to a SLES 15 guest. One of the Intel Ethernet Connection X722 for 1GbE adapters was used in this testing.
|
Adapters and Drivers
| | | | | |
| ATI
Integrated RN50 |
| | Driver Type: Video Driver | Driver Name: radeon_drv.so |
| | Driver Date: 25-Feb-2009 | Driver Size: 574040 |
| | Checksum: 46d5e45a3889d793b71ba18cc3470c0e |
|
| 4 HP
NetXen 375i |
| | Driver Type: LAN Driver | Driver Name: netxen_nic.ko |
| | Driver Date: 28-Feb-2009 | Driver Size: 91996 |
| | Checksum: 4fbc118a906cb44336a91e80e849be01 |
|
| HP
HP Smart Array P410i Controller |
| | Driver Type: HBA Driver | Driver Name: cciss.ko |
| | Driver Date: 28-Feb-2009 | Driver Size: 74216 |
| | Checksum: cfdccf9054a783a74eb530d325253751 |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Lenovo
For support regarding this specific configuration, please visit:
support.lenovo.com
|