 | ProLiant ML350 G6 2.93GHz Six Core
Network Server
Hitachi Vantara | 18 May 2010
132036 |
SUSE YES Certified for the following products:
Operating Systems:
| SUSE® Linux Enterprise Server 15 for AMD64 & Intel64 Service Pack 6 for SUSE® SLES 15 |
Product Description
For more information, please visit http://www.hp.com/go/proliantlinux
Tested Configuration:
| Computer Type: | Rack Mount |
| Mother Board Revision: | G6 |
| BIOS/uEFI: | D22 - 03/30/2010 |
| CPU: | 2 Intel
Xeon® Processor X5670 2.93 GHz |
| RAM: | 16 GB |
| Ports and Bus Types: | PCI Express X16 PCI Express X8 4 PCI Express X4 64-bit/100MHz PCI-X Serial 6 USB Ports |
| Video Adapter: | ATI
ES1000 |
| Host Bus Adapter: | HP
HP Smart Array P410i Controller
, Serial SCSI (SAS) Intel
Integrated 82801JI ICH10
, Serial ATA (SATA) |
| Hard Disk Drive: | HP
DB750BABFE 750GB 7200rpm SAS
, Serial SCSI (SAS) 3 HP
72GB 3G SAS
, Serial SCSI (SAS) |
| CD/DVD: | HLDS
DVD-ROM GDRH20N
, Serial ATA (SATA) |
| Floppy Type: | NONE |
| Test Kit: | System Certification Kit 6.5.0-0.30 |
Config Notes
- Install: The SLES install was performed using virtual DVD media.
- Kdump: The crash kernel memory parameters were increased from default to crashkernel: 768M high, crashkernel: 256M low using YaST.
|
Referenced Bulletins
153696
Adapters and Drivers
| | | | | |
| ATI
ES1000 |
| | Driver Type: Video Driver | Driver Name: radeon_drv.so |
| | Driver Date: 17-Mar-2008 | Driver Size: 283804 |
| | Checksum: 54e340ac765f3dcceb97d352ece9f560 |
|
| 2 HP
NC326i PCI Express Dual Port Gigabit |
| | Driver Type: LAN Driver | Driver Name: tg3.ko |
| | Driver Date: 05-Sep-2009 | Driver Size: 147140 |
| | Checksum: 50afa645d0c5e019fa4f40173d24a715 |
|
| HP
HP Smart Array P410i Controller |
| | Driver Type: HBA Driver | Driver Name: cciss.ko |
| | Driver Date: 05-Sep-2009 | Driver Size: 92464 |
| | Checksum: 42c9e6fa0309a9c5e603f02ab3e61a3c |
|
| Intel
Integrated 82801JI ICH10 |
| | Driver Type: HBA Driver | Driver Name: ata_piix.ko |
| | Driver Date: 05-Sep-2009 | Driver Size: 38728 |
| | Checksum: 0570b3a7035f99e94edbcf12f33799db |
|
The term SUSE YES Certified applies only to the exact configuration documented in this bulletin.
For more information on hardware exchange policies, please access the following document and view the Hardware Component Exchange Guide.
https://www.suse.com/product-certification/yes-certified/certification-requirements/
For more information regarding the specific test configuration, please contact:
Hitachi Vantara
2535 Augustine Drive
Santa Clara
, CA
95054
Voice: 1-408-970-1000
Toll Free: 1-800-227-1930
Fax: 1-408-727-8036